Chapter 4. Status Menu

Alarm Source

Alarm Message

Figure 4-3. Display of Alarm Message

View History

This menu item both displays and clears the accumulated sta- tus changes of the unit.

View History displays a history of the first 20 status changes in the unit, including the date, time, and type of change. The unit also records for viewing, the date and time an alarm became active and inactive, as well as the date and time of test activa- tion and deactivation.

To clear the View History display, press Clear (Shift+9) with the View History menu active.

Port Status

Port Status displays the signals monitored on the data ports. For example, the Nx/DBU interface monitors the RTS, CTS, and RD, along with other signal lines. When a port is selected, the LCD indicates if the signal is present.

The base Nx interface offers the status screen listed in this sec- tion. When using other option cards, refer to the appropriate separate manual for a definition of any status screens offered.

The Port Status of Nx/DBU is examined as an example of how to use this item. The DBU feature is available only in the TSU 120e.