ADTRAN TSU 120e user manual Data Port Identification, Exit Any Menu Field Operation Or Display

Models: TSU 120e TSU 120

1 140
Download 140 pages 56.89 Kb
Page 46
Image 46

Chapter 3. Operation

The equal symbol after LBO in the second line indicates the information that follows is displayed data and cannot be edited.

Exit Any Menu Field Operation Or Display

Press Cancel as many times as needed to return to the desired menu level or press Shift+0 (Home) to return to the main menu.

Data Port Identification

When configuring the unit, menu selections will include options from data port submenus. Selecting data ports is neces- sary because the TSU 120 uses a slot-port method to identify which data port the menu item is referencing. If a module con- taining a PBX DSX-1 option card with an Nx56/64 plug-on interface is installed in the option slot, it would be designated as:

DSX-1 Passthru=1.1 Where slot=1 and port =1.

The DSX-1 is located in the option slot and is the first port in that slot.

Nx56/64=1.2

Where slot=1 and port=2.

The Nx is located in the slot and is the second port in that slot.

The ports that are built into the TSU 120 are referenced as Slot 0. The Nx56/64 would be designated as 0.1 and the DSX-1would be referenced as 0.2.

3-8

TSU 120 User Manual

61202129L1-1

Page 46
Image 46