Chapter 3. Operation
The equal symbol after LBO in the second line indicates the information that follows is displayed data and cannot be edited.
Exit Any Menu Field Operation Or Display
Press Cancel as many times as needed to return to the desired menu level or press Shift+0 (Home) to return to the main menu.
Data Port Identification
When configuring the unit, menu selections will include options from data port submenus. Selecting data ports is neces- sary because the TSU 120 uses a
The
Nx56/64=1.2
Where slot=1 and port=2.
The Nx is located in the slot and is the second port in that slot.
The ports that are built into the TSU 120 are referenced as Slot 0. The Nx56/64 would be designated as 0.1 and the