Table 1-1. Specifications (continued)

TRANSIENT CURRENT LEVEL

 

 

Ranges

 

 

Low Range:

0 to 6 A

0 to 1 A

High Range:

0 to 60 A

0 to 10 A

Accuracy

 

 

Low Range:

± 0.1% ± 80 mA

± 0.18% ± 13 mA

High Range:

± 0.1% ± 350 mA

± 0.18% ± 50 mA

 

6060B

6063B

 

TRANSIENT RESISTANCE LEVEL

 

 

Ranges

 

 

Low Range:

0.033 to 1 W

0.20 to 24 W

Middle Range:

1 to 1000 W

24 to 10,000 W

High Range:

10 to 10,000 W

240 to 50,000 W

Accuracy

 

 

Low Range:

±0.8% ± 10 m W

± 0.8% ± 200 m W

 

with ³ 6 A at input

with ³ 1 A at input

Middle Range:

± 0.3% ± 10 mS

± 0.3% ± 0.5 mS

 

with ³ 6 V at input

with ³ 24 V at input

High Range:

± 0.3% ± 10 mS

± 0.3% ± 0.4 mS

TRANSIENT VOLTAGE LEVEL

with ³ 6 V at input

with ³ 24 V at input

 

 

 

 

Range:

0 to 60 V

0 to 240 V

Accuracy:

0.1% ± 300 mV

± 0.15% ± 1.1 V

CURRENT READBACK

 

 

 

 

*Accuracy:

0.05% ± 65 mA

± 0.12% ± l0mA

*after 30 second wait.

 

 

VOLTAGE READBACK

 

 

 

 

Accuracy:

0.05% ± 45 mV

± 0.1%150 mV

POWER READBACK

 

 

 

 

Accuracy

±0.2% ± 4 W

±0.2% ± 3 W

PARD (20 Hz to 10 MHz noise)

 

 

 

 

Current:

4 mA rms/40 mA p-p

1 mA rms/10 mA p-p

Voltage:

6 mV rms

6 mV rms

 

 

 

12 General Information

Page 12
Image 12
Agilent Technologies 5951-2826, 5951-2827 manual Current Readback