Programming

Programming Examples

Table 4-6

Couple Mode Example

 

 

 

 

Imports Agilent.TMFramework

 

Imports Agilent.TMFramework.DataAnalysis

 

Imports Agilent.TMFramework.DataVisualization

 

Imports Agilent.TMFramework.InstrumentIO

 

Module Module1

 

Sub Main()

 

Dim B2200 As New DirectIO("GPIB0::22::INSTR")

'8

Dim channels As String = "(@101,202,303,505)"

B2200.WriteLine("*RST")

'10

B2200.WriteLine(":ROUT:FUNC ACON")

B2200.WriteLine(":ROUT:CONN:RULE ALL,SROU")

 

B2200.WriteLine(":ROUT:CONN:SEQ ALL,BBM")

'13

B2200.WriteLine(":ROUT:COUP:PORT ALL,'3,5'")

B2200.WriteLine(":ROUT:COUP:STAT ALL,ON")

'15

B2200.WriteLine(":ROUT:CLOS " & channels)

MsgBox("Click OK to start measurement.", vbOKOnly, "")

 

Console.WriteLine("Measurement in progress. . ." & Chr(10))

 

'insert the code for measurement

'19

B2200.WriteLine(":ROUT:COUP:STAT ALL,OFF")

B2200.WriteLine(":ROUT:OPEN:CARD ALL")

 

B2200.Close()

 

MsgBox("Click OK to stop the program.", vbOKOnly, "")

 

Console.WriteLine("Measurement completed." & Chr(10))

'24

End Sub

 

End Module

 

Line

Description

 

 

 

 

8

Defines the channel list in the channels variable (string).

 

 

 

9 to 12

Resets the Agilent B2200. And sets the Auto configuration mode, the Single connection

 

rule, and the Break_Before_Make connection sequence.

 

 

 

 

13 to 14

Sets the couple ports, and turns the couple mode ON.

 

 

 

 

15

Closes switches to connect the input-output paths specified by channels.

 

 

 

15 to 25

Almost same as the code shown in the lines 13 to 22 of Table 4-3. The command used to

 

turn the couple mode OFF has been inserted to the line 19.

 

 

 

 

Agilent B2200 User’s Guide, Edition 2