| Language Dictionary - 6 |
cfMeasDCResistance | measures the dc resistance of a cell or all cells |
cfMeasOutputProbeResistance | measures the output probe resistance of a cell or all cells |
cfMeasProbeContinuity | checks the sense and output probe connections of a cell or all cells |
cfMeasSenseProbeResistance | measures the resistance looking into the sense probes of a cell or all cells |
cfMeasVoltage | measures the voltage of a cell or all cells |
cfOpen | opens a connection to the Agilent MCCD |
cfOpenGroup | associates a server handle with a defined group |
cfProtect | forces the Agilent MCCD into a protected state |
cfProtectClear | clears the protected state of the Agilent MCCD |
cfReadMeasLog | returns measurements acquired during a forming sequence |
cfReadTestLog | returns error messages from the test log |
cfReadSerial | reads data from one of the serial ports |
cfReset | sets programmable functions to their |
cfResetSeq | aborts and clears a previously defined sequence |
cfRestart | recalls a previously saved restart state |
cfSaveOutputConfig | saves the output configuration in |
cfSelftest | begins an instrument selftest |
cfSetAutoConnect | turns the automatic reconnect feature of the mccd.dll file on or off |
cfSetCurrent | sets the output current |
cfSetDigitalConfig | sets the operation of an individual digital I/O port |
cdSetDigitalPort | writes a data word to the digital I/O port |
cfSetErrorFunction | defines an error function |
cfSetGroup | defines a group of cells |
cfSetMeasLogInterval | defines the criteria for generating a measurement log entry |
cfSetOutputConfig | configures the output cells as active or inactive |
cfSetOutputProbeTest | sets the resistance limit of the output probe |
cfSetOutputState | sets the instrument’s output state off, charge, or discharge |
cfSetSense | sets the voltage sense to remote or local |
cfSetSenseProbeTest | sets the automatic testing of the sense probe resistance |
cfSetSeqStep | defines an output sequence step |
cfSetSeqTest | defines the tests performed during a sequence step |
cfSetSeqTestAnd | defines multiple tests combined with the logical AND function |
cfSetSerialConfig | sets the communication parameters of a serial port |
cfSetServerTimeout | sets the connection inactivity timeout period |
cfSetShutdownDelay | sets the shutdown delay period |
cfSetShutdownMode | sets the shutdown mode to auto or manual |
cfSetTimeout | sets the time the client waits for a response from the server |
cfSetTrigSource | sets the trigger source to LAN or external |
cfSetVoltage | sets the output voltage |
cfShutdown | causes the Agilent MCCD to go to a safe state prior to shutting down |
cfStateDelete | deletes a previously created instrument state |
cfStateList | returns a list of instrument state names |
cfStateRecall | loads a previously created instrument state |
cfStateSave | saves the present instrument settings in |
cfTrigger | sends a trigger over the LAN |
cfWriteSerial | writes data words to the serial port |
69