Chapter 3: Installing the Switch and Modules

Replacing Fan Module

The AT-FAN06 fan module is hot swappable within the chassis. The power to the chassis can remain ON while one of the fan modules is replaced. The following procedure assumes a second AT-FAN06 fan module is already installed and operating.

Perform the following procedure to replace an AT-FAN06 fan module:

Warning

The chassis cooling is designed to operate with two fan modules operating together. To avoid overheating of the AT-DC2552XS chassis, please complete the following procedure within one minute.

1.Loosen the captive screws on the AT-FAN06 fan module.

2.Gently pull the handle of the AT-FAN06 fan module to remove it from the chassis.

3.Slowly insert the new AT-FAN06 fan module into the vacant fan slot until it is flush with the front of the chassis.

The new AT-FAN06 fan module immediately powers up assuming the chassis power supplies are turned on.

4.Tighten the captive screws to fasten the fan module to the chassis. See Figure 23.

54

Page 54
Image 54
Allied Telesis AT-PWR06, AT-DC2552XS, AT-FAN06 manual Replacing Fan Module