Table 6: Supported Model-Unit Types for ignoreECC

Chapter 2. CLI Syntax Reference

Table 6: Supported Model-Unit Types for ignoreECC

Model

R-0

R-1

R-5

R-10

R-50

Single

JBOD

Spare

 

 

 

 

 

 

 

 

 

7K/8K

No

No

No

No

No

No

No

No

 

 

 

 

 

 

 

 

 

9K

No

Yes

Yes

Yes

Yes

No

No

No

 

 

 

 

 

 

 

 

 

name=string attribute allows you to name the new unit. (This feature is for 9000 series and above controllers.) The string can be up to 21 characters and cannot contain spaces. In order to use reserved characters (‘<‘, ‘>’, ‘!’, ‘&’, etc.) put double quotes (" ") around the name string. The name can be changed after the unit has been created. For more information, see “/cx/ux set name=string” on page 62 and “/cx/ux show name” on page 55.

storsave=protectbalanceperform attribute allows user to set the storsave policy of the new unit. This feature is only for 9550SX and 9590SE controllers. For more information, see “/cx/ux set storsave=protectbalanceperform [quiet]” on page 63.

/cx rescan [noscan]

This command instructs the controller to rescan all ports and reconstitute all units. The controller will update its list of ports (attached disks), and attempts to read every DCB (Disk Configuration Block) in order to re-assemble its view and awareness of logical units. Any newly found unit(s) or drive(s) will be listed.

noscan is used to not inform the operating system of the unit discovery. The default is to inform the operating system.

Note: If you are adding new drives, add them physically before issuing the rescan commands. Hot swap carriers are required unless you first power-down the system to prevent system hangs and electrical damage.

Example:

//localhost> /c1 rescan

Rescanning controller /c1 for units and drives ...Done Found following unit(s): [/c1/u3]

Found following drive(s): [/c1/p7, /c1/p8]

Note: Rescanning does not import non-JBOD on 7000/8000 models.