show ver

Shell Object Commands

(Not Optimal) state, RRate (Rebuild Rate) of 2, VRate (Verify Rate) of 5, BBU of '-' (Not Applicable). Not Optimal refers to any state except OK and VERIFYING. Other states include VERIFY-PAUSED, INITIALIZING, INIT-

PAUSED, REBUILDING, REBUILD-PAUSED, DEGRADED, MIGRATING, MIGRATE-PAUSED, RECOVERY, INOPERABLE, and UNKNOWN. RRate also applies to initializing, migrating, and recovery background tasks. (Definitions of the unit statuses are available in the 3ware Serial ATA RAID Controller User Guide.)

For a system with an enclosure unit such as the 3ware Sidecar that includes support for an EPCT (Enclosure Port Configuration Table), applicable firmware and software, and an appropriate controller (9550SX, 9590SE, or 9650SE), a global view of the environment also includes summary information about detected enclosures.

Example:

Typical output of the Show command for a system with an enclosure looks like the following:

//localhost> show

Ctl Model Ports Drives Units NotOpt RRate VRate BBU

---------------------------------------------------------------------------

c0

9590SE-4ME

4

2

1

0

4

4

-

Encl

Slots

Drives

Fans

TSUnits

 

Ctls

 

 

 

---------------------------------------------------

 

 

 

e0

4

2

1

1

 

1

 

 

 

The output above shows the enclosure summary information with the name of the enclosure, the protocol used, the number of drive slots, the number of drives, the number of fans, the number of temperature sensors, and the number of controllers that are associated with the enclosure.

show ver

This command will show the CLI and API version.

Example:

//localhost> show ver CLI Version = 2.00.00.0xx API Version = 2.00.00.0xx

where xx is the actual version. See the Release Notes for details.

www.3ware.com

21