Manuals
/
AMCC
/
Computer Equipment
/
Computer Hardware
AMCC
9590SE-4ME manual 3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Models:
9590SE-4ME
1
8
93
93
Download
93 pages
38.98 Kb
5
6
7
8
9
10
11
12
<
>
Install
Maintenance
Available RAID Configurations
Setting Up a Rebuild Schedule
Command Line Interface
show alarms reverse
Setting Auto-Carving Policy on /c0 to on ... Done
How to
cx/ux show volumes
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Page 8
Image 8
2
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Page 7
Page 9
Page 8
Image 8
Page 7
Page 9
Contents
Command Line Interface
Supports the 9590SE-4ME for the Power Mac G5
CLI Guide for the Power Mac G5
3ware
Disclaimer
Copyright
Trademarks
Chapter 1. Introduction to the 3ware Command Line Interface
Chapter 2. CLI Syntax Reference
Table of Contents
Using the command interface interactively
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
cx/ux remove noscan quiet
cx/ux del noscan quiet
cx/ux set autoverify=onoff
cx/ux set identify=onoff
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Return Code
About this CLI Guide
Table 1 Sections in this CLI Guide
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Introduction to the 3ware Command Line Interface
Features of the CLI
Supported Operating Systems
Terminology
Installing the 3ware CLI on Mac OS
To install 3ware CLI on Mac OS
Working with 3ware CLI
Permissions Required to Run CLI
Using the command interface interactively
Using a single command with output
Syntax
Example
Using an input file to execute a script
Outputting the CLI to a Text File
Scripting example
Examples
Understanding RAID Levels and Concepts
Conventions
RAID Concepts
Available RAID Configurations
RAID
Figure 1. RAID 0 Configuration Example
Figure 2. RAID 1 Configuration Example
RAID
RAID
RAID
Figure 3. RAID 5 Configuration Example
Figure 4. RAID 10 Configuration Example
Hot Spare
Determining What RAID Level to Use
Single Disk
Using Drive Capacity Efficiently
Table 3 Drive Capacity
Common Tasks Mapped to CLI Commands
CLI Syntax Reference
Table 4 Common Tasks Mapped to CLI Commands
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
CLI Command
Controller Configuration Tasks
Common Tasks Mapped to CLI Commands
Table 4 Common Tasks Mapped to CLI Commands
CLI Command
Unit Maintenance Tasks
Syntax Overview
Syntax
Shell Object Commands
focus Object
show
show ver
show rebuild
show alarms reverse
show diag
show verify
show selftest
update fw=filenamewithpath force
flush
rescan
commit
Controller Object Commands
Controller Object Commands
Syntax
cx add rebuild=dddhhduration
cx show
cx show attribute attribute
cx show bios
cx show driver
cx show model
cx show firmware
cx show serial
cx show pcb
cx show pchip
cx show achip
cx show numports
cx show numunits
cx show ctlbus
cx show exportjbod
cx show spinup
cx show stagger
cx show ondegrade
cx show autocarve
cx show carvesize
cx show memory
localhost /c0 show memory /c0 Memory Installed = 112MB
localhost /c0 show autocarve /c0 Auto-Carving Policy = on
cx show autorebuild
cx show unitstatus
cx show allunitstatus
cx show drivestatus
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Chapter 2. CLI Syntax Reference
Controller Object Commands
cx show all
Example where x represents the actual version number
Table 5 Supported Stripe Sizes
group=3456 indicates the number of disks per group for a RAID 50 type. This attribute can only be used when type=raid50. Recall that a RAID 50 is
cx rescan noscan
Table 6 Supported Model-Unit Types for ignoreECC
cx flush
cx update fw=filenamewithpath force
cx commit
cx show alarms reverse
cx show diag
Recommendation No need to update Given the above recommendation
The new image will take effect after reboot
cx show rebuild
If the rebuild schedule is enabled while a rebuild process is underway, the rebuild will pause until a scheduled time slot
cx show verify
Controller Object Commands
cx show selftest
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
cx add rebuild=dddhhduration
Setting Up a Rebuild Schedule
To set up the rebuild schedule you want to use, follow this process
cx add verify=dddhhduration
Setting Up a Verify Schedule
To set up the verify schedule you want to use, follow this process
Setting Up a Selftest Schedule
To set up the selftest schedule you want to use, follow this process
cx add selftest=dddhh
cx del rebuild=slotid
cx del selftest=slotid
cx set rebuild=enabledisable1..5
cx del verify=slotid
cx set exportjbod=onoff
cx set verify=enabledisable1..5
cx set selftest=enabledisable task=UDMASMART
cx set ondegrade=cacheofffollow
cx set spinup=nn
cx set stagger=nn
cx set autocarve=onoff
cx set carvesize=1024..2048
cx set autorebuild=onoff
Setting Auto-Carving Policy on /c0 to on ... Done
Setting Auto-Carving Size on /c0 to 2000 GB ... Done
cx start mediascan
cx stop mediascan
Syntax
Unit Object Commands
cx/ux show
cx/ux show attribute attribute
cx/ux show status
cx/ux show rebuildstatus
cx/ux show verifystatus
cx/ux show initializestatus
cx/ux show name
cx/ux show qpolicy
cx/ux show storsave
cx/ux show identify
cx/ux show autoverify
cx/ux show volumes
cx/ux show cache
cx/ux show ignoreECC
cx/ux show all
Example of interactive mode //localhost /c0/u0 export
cx/ux remove noscan quiet
cx/ux del noscan quiet
Are you sure you want to delete the unit /c0/u0? Enter Y to continue
cx/ux start rebuild disk=pp-p... ignoreECC
cx/ux start verify
cx/ux pause rebuild
cx/ux resume rebuild
cx/ux stop verify
Table 7 Supported RAID Logical Unit Types for Verification
cx/ux flush
cx/ux set autoverify=onoff
cx/ux set cache=onoff quiet
Table 8 Supported RAID Types for Caching
cx/ux set identify=onoff
cx/ux set ignoreECC=onoff
cx/ux set name=string
cx/ux set qpolicy=onoff
localhost /c0/u5 set qpolicy = on
cx/ux set storsave=protectbalanceperform quiet
Setting Command Queuing Policy for unit /c0/u5 to on ... Done
Setting Command Storsave Policy for unit /c0/u5 to protect Done
localhost /c0/u5 set storsave=protect
Table 9 Valid Migration Paths
Table 10 Supported Stripe Sizes
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Migration Process
Example of splitting a mirror
Example of capacity expansion
Example of migrate output
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Chapter 2. CLI Syntax Reference
Port Object Commands
cx/px show
cx/px show attribute attribute
Syntax
cx/px show status
cx/px show model
cx/px show serial
cx/px show firmware
cx/px show ncq
cx/px show lspeed
cx/px show capacity
cx/px show smart
cx/px show all
3ware Serial ATA RAID Controller CLI Guide for the Power Mac G5
Chapter 2. CLI Syntax Reference
Example
cx/px remove noscan quiet
cx/px set identify=onoff
Setting Port Identify on /c0/p5 to on ... Done
localhost /c0/p5 set identify=on
Syntax
BBU Object Commands
cx/bbu show
cx/bbu show attribute attribute
cx/bbu show status
cx/bbu show batinst
cx/bbu show lasttest
cx/bbu show volt
cx/bbu show temp
cx/bbu show bootloader
cx/bbu show serial
cx/bbu show fw
cx/bbu show pcb
cx/bbu enable
cx/bbu disable quiet
Syntax
Enclosure Object Commands
ex show
ex show slots
ex show attribute attribute
ex show controllers
ex show fans
ex show temp
ex show all
ex/slotx show
ex/slotx show identify
ex/slotx set identify=onoff
ex/fanx show
ex/tempx show
Help Commands
Help with specific commands
Help with attributes
help
help show
help flush
AMCC/3ware CLI version Commands Description
help update
help rescan
help commit
help focus
Return Code
help /cx/bbu
help /ex