/cx/bbu show serial

BBU Object Commands

/cx/bbu show serial

This command shows the BBU serial number.

/cx/bbu show fw

This command shows the BBU firmware version number.

/cx/bbu show pcb

This command shows the PCB revision number on the BBU.

/cx/bbu show bootloader

This command shows the BBU's boot loader version.

/cx/bbu show all

This command shows the current settings of all BBU-related attributes: ready, status, batinst, lasttest, volt, temp, cap, serial, fw, pcb, bootloader.

Example:

//localhost> /c1/bbu show all

= BBU: 1.04.00.007

/c1/bbu Firmware Version

/c1/bbu Serial Number

= Engineering Sample.

/c1/bbu BBU Ready

= Yes

/c1/bbu BBU Status

= OK

/c1/bbu Battery Voltage

= OK

/c1/bbu Battery Temperature

= OK

/c1/bbu Estimated Backup Capacity

= 241 Hours

/c1/bbu Last Capacity Test

= 22-Jun-2004

/c1/bbu Battery Installation Date

= 20-Jun-2004

/c1/bbu Bootloader Version

= BBU 0.02.00.002

/c1/bbu PCB Revision

= 65

//localhost>

 

/cx/bbu test [quiet]

This command starts the battery capacity test. The test may take up to 24 hours to complete. During the test, the BBU is not capable of backup operation and the write cache of all units attached to that controller is disabled. Once the test is completed with no error and the BBU status returns to OK, the write cache will be re-enabled.