Chapter 2 Specifications
COM 830 Reference Manual 9
Environmental Specifications
Temperature Operation: 0° to 60°C Storage: -20° to +80°C
Humidity Operation: 10% to 90% Storage: 5% to 95%
Ampro strongly recommends that you use the appropriate module heatspreader as a thermal interface
between the module and your application’s cooling solution.
If for some reason it is not possible to use the appropriate module heatspreader, then it is the responsibility
of the operator to ensure that all components found on the module operate within the component
manufacturer’s specified temperature range.
Table 2-4. COM830 Intel® Celeron M 423 1.0 7GHz 1MB L2 cache
COM 830-R-10 Intel® Celeron M 423 1.06GHz 1MB L2 cache
ULV 65nm
Memory Size 512MB
Operating System Windows XP Professional SP2
Power State Desktop Idle 100%
workload Standby (S1) Suspend to
Ram (S3)
Power consumption
(measured in Amperes/Watts)
1.26A/15.10W 1.90A/2 2.82W 1.60A/19.23W 0.82A/9.86W
NOTE All recorded power consumption values are approximate and only valid for the
controlled environment described earlier. Power consumption results will vary
depending on the workload of other components such as graphics engine,
memory, etc.
CAUTION The above operating temperatures must be strictly adhered to at all times.
When using a heatspreader the maximum operating temperature refers to
any measurable spot on the heatspreader's surface.