Chapter 2Specifications
Table
COM | Intel® Celeron M 423 1.06GHz 1MB L2 cache |
| ||
| ULV 65nm |
|
|
|
Memory Size | 512MB |
|
|
|
Operating System | Windows XP Professional SP2 |
|
| |
Power State | Desktop Idle | 100% | Standby (S1) | Suspend to |
|
| workload |
| Ram (S3) |
Power consumption | 1.26A/15.10W | 1.90A/22.82W | 1.60A/19.23W | 0.82A/9.86W |
(measured in Amperes/Watts) |
|
|
|
|
|
|
|
|
|
NOTE All recorded power consumption values are approximate and only valid for the controlled environment described earlier. Power consumption results will vary depending on the workload of other components such as graphics engine, memory, etc.
Environmental Specifications
Temperature Operation: 0° to 60°C Storage:
Humidity Operation: 10% to 90% Storage: 5% to 95%
CAUTION The above operating temperatures must be strictly adhered to at all times. When using a heatspreader the maximum operating temperature refers to any measurable spot on the heatspreader's surface.
Ampro strongly recommends that you use the appropriate module heatspreader as a thermal interface between the module and your application’s cooling solution.
If for some reason it is not possible to use the appropriate module heatspreader, then it is the responsibility of the operator to ensure that all components found on the module operate within the component manufacturer’s specified temperature range.
COM 830 | Reference Manual | 9 |