4.5 Data/Event Logging

To enable logging and to specify which data and events are included in logging, select 4 from the Main menu. Select items from the Data/Event Logging menu using the screen listing below.

--------------------- LOGGING

MENU

----------------------

1-Power Events: ON

3-

UPS Faults: ON

2-UPS Control: ON

4- User Activity: ON

 

5-

Measure-UPS: OFF

Date: Jul-27 ’97

 

Time: 15:05:35

---------------------------------------------------------

Jul-27 15:01:12 UPS Returned On Line

Jul-27 15:01:34 Shut Down Until Power Returns Jul-27 15:01:38 Power Restored, Load Powered ON

---------------------------------------------------------

6- List Event Groups

7- View Event Log

8- Reset Event Log

9- Log UPS Data to screen

10- Log Interval: 1 min

11- Data Format: Text ?- Help

<ENTER> Display menu

<ESC> Return to Previous menu

>

The following is a sample Call-UPSIIUPS data log, with Data Format set to Text:

Jul-27

’97 14:42:39

 

 

 

Line:117.8VAC

Max:119.0VAC

Min:117.1VAC

Batt:27.67VDC

Freq:60.00Hz

Temp:025.2C

Load:017.6%

 

Jul-27

’97 14:43:39

 

 

 

Line:119.0VAC

Max:119.0VAC

Min:117.8VAC

Batt:27.67VDC

Freq:60.00Hz

Temp:025.2C

Load:017.6%

 

Jul-27

’97 14:44:39

 

 

 

Line:119.0VAC

Max:119.0VAC

Min:117.8VAC

Batt:27.67VDC

Freq:60.00Hz

Temp:025.2C

Load:018.7%

 

Jul-27

’97 14:45:39

 

 

 

Line:118.4VAC

Max:119.0VAC

Min:117.8VAC

Batt:27.67VDC

Freq:60.00Hz

Temp:025.6C

Load:018.7%

 

For a description of the items on the Data/Event Logging menu, refer to the table that follows.