DCP Cabling and Administration

9-11

_______________________________________________________________________________________

_

2.Assign all four extensions (or six if you are converting RS-232 ports to DCP) to Bearer Capability Class-Of-Service (BCCOS) 6 as shown in Figure 9-5, Manager II Administration of a DCP Port (Proc 000, Word 3). The extension number shown is only an example.

NOTE

The default BCCOS 0 through 8 should not be modified to support AUDIX networking. If a custom BCCOS is required, create a new BCCOS using the default values shown in PROC 014, Words 1 and 2. Refer to the DEFINITY Generic 2 Administration Procedures manual (555-104-506) if needed.

The BCCOS 6 default parameters are also shown in Figure 9-6,Manager II Administration of a DCP Port (Proc 014, Word 1), and Figure 9-7,Manager II Administration of a DCP Port (Proc 014, Word 2).

 

ENHANCED

MODE - PROCEDURE: 000, WORD: 3

 

SINGLE TERMINAL - MISCELLANEOUS FEATURES

1.

 

Extension:

32330

 

2.

 

Hot Line:

0

Not a hot line

3.

Dedicated Switch Connection

Messages:

0

Not supported (TDM, PDM, DTDM)

4.

Audible Message Waiting - Automatic:

0

Disabled

5.Bearer Capability Class of Service: 6

6.Universal Code Calling ID: ---

Connected to CC0 ON-LINE

MAJOR

MINOR

RUN TAPE

BUSY OUT

IN USE

WAIT

enter command: _

3 Data

5 Help 6 Field 7 Input 8 Cmds

Figure 9-5.Manager II Administration of DCP Port (Proc 000, Word 3)

Page 101
Image 101
AT&T 585-300-903 manual Manager II Administration of DCP Port Proc 000, Word