AT&T 585-300-903 manual Saving Data

Models: 585-300-903

1 268
Download 268 pages 19.87 Kb
Page 175
Image 175

AUDIX System Administration

13-21

_______________________________________________________________________________________

_

For an AT&T Paradyne model 3820 modem connected to the RS-232 ports (not in a modem pool), enter the following for 9600 bps asynchronous operation. The same string should be used for the modem at the called system:

at&f0 &d2 m0 \n1 \q3 s0=1 s2=128 s76=1 s78=1 s41=3 &w0

A Telebit T1000 stand-alone modem may be connected to the RS-232 ports (not in a modem pool). When the modem is first installed, power it up, open the front panel, and push the RESET button. This puts the modem in conventional mode. You can then enter the following dial string for 9600 bps asynchronous operation. The same string should be used for the modem at the called system:

at &fm0 &d2 &c1 &k3 s0=1 s2=128 &w0 &y0

For T1000 modems only, the System 75, Generic 1, or Generic 3 analog stations form must have the distinctive audible alert field set to n.

NOTE

Telebit modems can only make or receive calls from another Telebit modem (such as another T1000). This modem is only certified to work on RS-232 ports 5 and 6.

modem initialization status

This display-only field should be blank. If it is not blank, it is displaying the status of a previous initialization and it will be updated when you save your data.

DCP ports — data rate for incoming mode 2 calls or 0 if channel not used

This field does not apply for systems with the TN366 or TN366B. For systems with the TN539 or TN539B, this field indicates the data rate that the TN539 or TN539B will specify in response to a "data options query" from the switch for an incoming DCP Mode 2 call (a call that uses modem pooling to access this remote system). Permissible values are 0, 1200, 2400, 4800, 9600, and 19200. If the DCP channels are not to be used, enter 0 in each field. For System 75, Generic 1, or Generic 3, enter 0 for channel 2 and channel 4.

If the AUDIX system is using a 7400A or 7400B to talk with another AUDIX system that also uses a 7400A/B, the incoming DCP mode 2 data speed should match the speed set on the 7400A/B.

If the AUDIX system is receiving mode 2 calls from other AUDIX systems as well, and these systems use speeds different from the 7400A/B, multiple speeds can be entered on the form. Contact the BCSDC for information on using multiple speeds.

Saving Data

After you have completed this form, press

CHANGE or RUN

to save any changes or additions.

If initialization strings were entered, the AUDIX system will now send these strings to the modems to initialize them. The modem initialization status fields show ‘‘pending’’. After a few seconds, press

ENTER to display the status of this new initialization attempt. If ‘‘pending’’ is still displayed, repeat the wait-and-press ENTER procedure until some result is displayed. When a result is displayed, press SHIFT and TAB at the same time to get to the modem initialization status fields. Then press f5 (field help) for an explanation of the result.

Page 175
Image 175
AT&T 585-300-903 manual Saving Data