LOOPBACK TESTING FOR INTERLOCATED SYSTEMS

If the AUDIX systems to be networked are at different locations (interlocated) and a serving office (SO) will provide 64 Kbps service, you will need to test the connection between the local AUDIX system and the 64 Kbps serving office (SO), as shown in Figure 12-2, 64 Kbps Network Loop-Around Test. If you have R1V7 software, you can do this via the maintenance : network form for the DCP ports (ports 1-4). If you have an MPDM/M1* connected to ports 5 and 6, they may also be tested for 64 Kbps operation using this form.

While a channel is in loopback mode, it will be unavailable to send information to remote systems or receive information from remote systems. Incoming calls will be answered, but the calling system will be unable to establish a connection; eventually it will drop the call and attempt to call back at its next scheduled transmission time.

Also, if you put a channel in loopback mode, any active calls will be dropped. It is therefore recommended before you perform this test you check the status of the channel. It is also not a good idea to perform this test during peak traffic times.

1. Go to the maintenance : network form. Set select test to 8 to test a 64 Kbps network

connection. Press

 

 

TAB

 

to get to the channel field and then specify the channel (1-6) you want to

 

 

 

 

 

 

 

 

 

 

 

 

and wait for the result.

use for the test. Press

 

 

 

CHANGE or RUN

 

 

 

 

 

 

NOTE

If you have an MPDM/M1* between the AUDIX system and the PBX, you may also test channels 5 or 6 (the RS-232 channels) for 64 Kbps operation.

2.Have the serving office place a call to the telephone number assigned to the channel you specified on the maintenance : network form. If the test is successful, any data the serving office sends over the AUDIX channel will be echoed back.

3.Go to the maintenance : network form. Set select test to 9 to take the channel out of

loopback mode. Press

 

 

TAB

 

 

 

to get to the channel field and then specify the channel (1-6) you want

 

 

 

 

to take out of loopback

 

 

Press

 

 

 

 

 

and wait for the result.

mode.

CHANGE or RUN

 

 

 

 