AT&T 585-300-903 manual 13-26AUDIX System Administration

Models: 585-300-903

1 268
Download 268 pages 19.87 Kb
Page 180
Image 180

13-26AUDIX System Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

3.Log back on to system 2 using an administration or maintenance terminal and add the subscriber(s) using the subscriber : local form.

4.From a voice terminal, log in to system 2 using the administrator’s login. Go to voicing in the name and record the subscriber’s name.

If the name-record-by-subscribers feature is used, names will not be recorded until the first time subscribers log in to the AUDIX system.

5.Run a connection test from system 2 to all other systems and from all other systems to system 2. (Or wait for the transmission intervals.)

6.Log in to system 1 using an administration or maintenance terminal. Look at the subscriber : remote form to see that the subscriber(s) is now listed as a remote subscriber(s). If the subscriber(s) is not listed, check the system : log form for ‘‘a full update has been requested’’. If this is the case, you must do a full update from system 1 to system 2 using the system : translation : remote updates form.

7.Repeat step 6 for the other systems remote to system 2.