A-6Network Considerations

________________________________________________________________________________________________

________________________________________________________________________________________________

DCP Extension

The switch data port extensions used for the AUDIX DCP network ports. System 85

Numbers

and DEFINITY Generic 2 traditional modules require four extensions assigned in a

 

hunt group. Make the hunt group accessible to Direct Inward Dialing (DID), DCS, or

 

tie trunks (DID is the most common). Generic 2 universal modules require at least a

 

TN366B vintage 2 ACC, a TN539 vintage 4, or a TN539B ACCE in the AUDIX

 

system in order to support four channels.

 

System 75, System 75 XE, Generic 1, Generic 3, and MERLIN II require two

 

extensions. If the Generic 2 universal module is connected to a TN366 or TN366B

 

vintage 1 ACC, it is also limited to two extensions.

RS232

The RS-232 numbers refer to the new ports (channels 5 and 6) available in R1V5 or

Connectivity

later AUDIX systems equipped with a TN539 or TN539B ACCE. Two extension

Extension

numbers are required and should be in their own hunt group with a DID number as the

Numbers

lead extension.

 

This field refers to analog RS-232 connections where the AUDIX system is to be

 

accessed via a switched RS-232 connection (that is, the AUDIX system will be cabled

 

to a switch port through a modem). This is specified as an rs232a (asynchronous)

 

type of connection on the AUDIX system : translation : network

 

port form.

NOTE

If one AUDIX system is directly connected to another through a null-modem cable, no switch extension numbers are necessary.

RS232

The RS-232 numbers refer to the new ports (channels 5 and 6) available in R1V5 or

(Converted to

later AUDIX systems equipped with a TN539 or TN539B ACCE. This field refers to

DCP

digital RS-232 connections where the AUDIX system is to be accessed via an

Connectivity)

MPDM/M1* or 7400A data module. This is specified as an rs232s (synchronous)

Extension

type of connection on the AUDIX system : translation : network

Numbers

port form.

Hunt Group

On System 75, DEFINITY Generic 1, or Generic 3 systems, this is the soft extension

Extension

(DID) number used to access the AUDIX network hunt group. Typically only one

Number(s)

hunt group is assigned.

Equipment

This is the equipment location code for the DCP and/or RS-232 ports (formerly called

(Switch Ports)

the Equipment Line Location).

Dial String

At times it is appropriate for AUDIX to use the switch’s routing features. Select any

 

that apply to your switch and indicate the Feature Access Code (FAC), Trunk Access

 

Code (TAC), or Trunk Group (TG) as required.

Switchroom

DID telephone number of the switch room. This number is used to contact the

Number

technician.

AUDIX Remote

The Remote Maintenance Terminal (RMT) DID number assigned to the modem

Maintenance

connected to the AUDIX maintenance port H00. This allows remote services

Number

personnel to log in for troubleshooting and/or administration.

Page 228
Image 228
AT&T 585-300-903 DCP Extension, Numbers, RS232, Connectivity, Converted to, Hunt Group, Equipment, Dial String, Switchroom