DCP Mode 2 Networks — Modem Pooling

5-11

_______________________________________________________________________________________

_

Rack-Mount Equipment

The following equipment is required when rack-mounted modem pools are used (i.e., a D-Lead modem pool):

72-inch Data or Auxiliary Cabinet and power supply

The 2296A requires a 105A mounting

One of the following multi-mounts for the data sets:

The MTDM requires a 46A2 mounting

The 7400A requires a 77A mounting

Cabling

Cabling for multi-mount arrangements is provided with the cabinet and the mountings. One D-Lead cable (RS-232C to 25-pair cable), one 25-pair cable for each mounting, and one M25 RS-232C cable for each modem pool pair is required.

Cabling for stand-alone modem pools consists of a 104A adapter, an M25 RS-232C cable (male-male), a D8W-87 modular cord, and building wire for each pair.

DATA RATES FOR DCP MODE 2

This arrangement operates at speeds up to and including 9.6 Kbps (the limit for modem pooling).

DCP MODE 2 FOR A 5ESS SWITCH

The System 75, System 85, DEFINITY Generic 1, Generic 2, Generic 3, and DIMENSION PBX systems support the DCP interface. If the customer has an AUDIX system serving another switch and would like to network the AUDIX system with another location, they could use an AT&T digital PBX for its DCP and modem pooling capabilities. A picture of the DCP Mode 2 arrangement is shown along with a DCP Mode 3 arrangement in Chapter 6, DCP Mode 3 Networks — 64 Kbps.

Page 65
Image 65
AT&T 585-300-903 manual DCP Mode 2 for a 5ESS Switch, Rack-Mount Equipment, Cabling