CHANGE or RUN

AUDIX Network Testing

14-25

_______________________________________________________________________________________

_

Step 3: Performing Channel or Modem Loop-Around Tests

If the appropriate tests in step one and step two fail, perform the appropriate test:

Channel internal loop-around test

Modem loop-around test

Step 3A: Channel Internal Loop-Around Test

This test is used to verify the operation of an individual channel on the ACC or ACCE board. No connection (that is, no call) is needed for this test.

1.Go to the maintenance : network form.

2.Set select test to 2.

3. Go to channel and enter 1, 2, 3, or 4. Press CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or go to Flowcharts For Troubleshooting the Network.

NOTE

Use the modem loop-around test (test 6) for channel 5 or 6.

Step 3B: Modem Loop-Around Test

This test is only for modems connected to the RS-232 channels (that is, channel 5 or channel 6). It will test the loop to the modem and back. No action is required at the modem for this test.

1.If you are not using a MICROCOM QX 3296/C modem, go to step 2. If you are testing a MICROCOM QX 3296/C modem, you must first go to the system : translation : network port form. Record the three data rate fields and the modem initialization string field for the channel to be tested. These values will be restored once the test is completed. Now change the data rate fields to 2400 and change the modem initialization string field to AT\n0. Press

.

2.Go to the maintenance : network form. Set select test to 6. Set channel to 5 or 6. Press CHANGE or RUN . Wait for the result. If the test is not successful, check the system : log and/or

go to Flowcharts For Troubleshooting the Network.

3.If you are testing a 3296/C, go back to the system : translation : network port and restore the original translations.

Page 207