AT&T 585-300-903 manual H600-331, Group 1 Cable, H600-331, Group 2 Audix Networking Breakout Cable

Models: 585-300-903

1 268
Download 268 pages 19.87 Kb
Page 29
Image 29

Introduction 1-9

_______________________________________________________________________________________

_

CONNECTS TO AUDIX

ACCE PORT

2.4 FT. (0.73M)

AMPHENOL 50-PIN

FEMALE CONNECTOR

UP TO 200 FT (60.96M)

PATCH TO CROSS-CONNECT FIELD

AMPHENOL 50-PIN

MALE CONNECTOR

A

B

5.0 FT (1.524 M)

ED-1E434-11 GROUP 300

50 PIN MALE-MALE

OR

ED-1E434-11 GROUP 500 50 PIN MALE-FEMALE

CONNECT TO DEDICATED OR SWITCHED RS-232

ENDPOINTS

RS-232 25-PIN

MALE CONNECTORS

Figure 1-2.H600-331, Group 2 AUDIX Networking Breakout Cable

H600-331, Group 1 Cable

The H600-331, Group 1 breakout cable is no longer shipped; only an AUDIX system that is already installed will have the Group 1 networking cable. One end of this cable is a 50-pin male Amphenol connector that connects to the ACC or ACCE on the AUDIX system. The other end of the cable has two 8-pin DCP connectors and two 25-pin RS-232 male connectors. See Table 1-2for pin assignments.

The H600-331, Group 1 DCP connector 0 provides access to two DCP channels (AUDIX networking channels 1 and 2). DCP connector 1 also provides access to two DCP channels (AUDIX networking channels 3 and 4). The two 451A adapters are shipped on the ends of connectors 0 and 1. The D8W-87 extension cords and 103A adapters must be ordered separately.

The H600-331, Group 1 RS-232 connector A also provides access to one RS-232 channel (AUDIX networking channel 5), and RS-232 connector B provides access to another RS-232 channel (AUDIX networking channel 6).

Page 29
Image 29
AT&T 585-300-903 manual H600-331, Group 1 Cable, H600-331, Group 2 Audix Networking Breakout Cable