9-10DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

Manager II Administration

Manager II assignments for Generic 2 are as follows:

1.Assign all four extension numbers (or six if you are converting RS-232 ports to DCP) to the system (Proc 000, Word 1) as shown in Figure 9-4, Manager II Administration of a DCP Port (Proc 000, Word 1). The extension number shown is only an example; use the extension numbers provided by the BCSDC.

Use a class-of-service (Proc 010, Word 1 and Word 3) that has touch-tone dialing capability and data protection – permanent. Class of service 10 is only an example.

ENHANCED MODE - PROCEDURE: 000, WORD: 1

SINGLE TERMINAL TRANSLATION

1.Extension or VDN: 32330

TERMINAL EQUIPMENT LOCATION

2.Module: --

3.Cabinet: -

4.Carrier: -

5.Slot: --

6.Circuit: --

7.Class of Service: 10

8.Port Type: - Extension administered in Procedure 052 Word 1

9.Disable Signaling: - Non-DS1 lines

DISPLAY ONLY

10.Recent Disconnect: 0 Extension is not in recent disconnect

11.Use the Procedure(s) Shown: 052

Connected to CC0 ON-LINE

MAJOR

MINOR

RUN TAPE

BUSY OUT

IN USE

WAIT

enter command: _

3 Data

5 Help 6 Field 7 Input 8 Cmds

Figure 9-4.Manager II Administration of DCP Port (Proc 000, Word 1)

Page 100
Image 100
AT&T 585-300-903 manual Manager II Administration, 10DCP Cabling and Administration