AT&T 585-300-903 manual 12DCP Cabling and Administration, Call Types and Action Taken

Models: 585-300-903

1 268
Download 268 pages 19.87 Kb
Page 102
Image 102

9-12DCP Cabling and Administration

________________________________________________________________________________________________

________________________________________________________________________________________________

ENHANCED MODE - PROCEDURE: 014, WORD: 1

 

BEARER CAPABILITY CLASS

OF SERVICE - CALL OPTIONS

 

1.

Bearer Capability COS: 6

DEFAULT CAPABILITIES

 

2.

Transport Mode:

0

Circuit

14.

Transport

Mode: 0

Circuit

3.

Information Type:

0

Restrict

15.

Information

Type: 0

Restricted

 

 

 

 

16.

Bearer Capability: 4

Mode 0

CALL TYPES AND ACTION TAKEN

4.Voice: 0 Circuit switch the call

5.Voice Grade Data: 1 Insert a mode 2-to-analog modem pool facility

6.Mode 0: 0 Circuit switch the call

7.Mode 1: 0 Circuit switch the call

8.Mode 2: 0 Circuit switch the call

9.Mode 3: 0 Circuit switch the call

10.Unknown Digital: 0 Circuit switch the call

11.Unknown Analog: 1 Insert a mode 2-to-analog modem pool facility

12.Mode 3/2: 0 Circuit switch the call

13.X.25: 0 Circuit switch the call

Connected to CC0 ON-LINE

MAJOR

MINOR

RUN TAPE

BUSY OUT

IN USE

WAIT

enter command: _

3 Data

5 Help 6 Field 7 Input 8 Cmds

Figure 9-6.Manager II Administration of DCP Port (Proc 014, Word 1)

3.The DCP extensions default to BCCOS 1. Change this to BCCOS 6 as shown in these examples. This allows the DCP port to communicate with either a digital or analog outside facility.

A call to/from this port will be circuit switched unless it is voice-grade data or unknown analog. In these cases, a modem pool will be inserted.