Chapter 3. Administrator Utility
7.Click Upgrade to begin upgrading the firmware.
Click Abort to cancel the firmware upgrade. The KM0832 will automatically reboot, requiring you to log in again.
Note: It takes approximately 7 minutes to upgrade the firmware for a single stage installation, or 17 minutes for a cascaded installation. Please be patient while the firmware is upgrading.
8. After the firmware upgrade completes, log out to reset the KM0832.
Upgrade Failed
If a device fails to complete the upgrade successfully, start the firmware upgrade procedure again (see page 66).
Firmware Upgrade Recovery
If the firmware upgrade procedure is aborted prematurely (due to a power outage, for example), the switch that was being upgraded at the time may become inoperable, and may be incapable of accepting a normal firmware upgrade.
To recover from a failed firmware upgrade:
1.Slide the firmware upgrade recovery switch (see page 8) to the RECOVER position.
2.Perform a system reset (see System Reset Button on page 7).
3.Slide the recovery switch back to the NORMAL position.
4.Start the firmware upgrade procedure again (see page 66).
67