Chapter 3. Administrator Utility

7.Click Upgrade to begin upgrading the firmware. -or-

Click Abort to cancel the firmware upgrade. The KM0832 will automatically reboot, requiring you to log in again.

Note: It takes approximately 7 minutes to upgrade the firmware for a single stage installation, or 17 minutes for a cascaded installation. Please be patient while the firmware is upgrading.

8. After the firmware upgrade completes, log out to reset the KM0832.

Upgrade Failed

If a device fails to complete the upgrade successfully, start the firmware upgrade procedure again (see page 66).

Firmware Upgrade Recovery

If the firmware upgrade procedure is aborted prematurely (due to a power outage, for example), the switch that was being upgraded at the time may become inoperable, and may be incapable of accepting a normal firmware upgrade.

To recover from a failed firmware upgrade:

1.Slide the firmware upgrade recovery switch (see page 8) to the RECOVER position.

2.Perform a system reset (see System Reset Button on page 7).

3.Slide the recovery switch back to the NORMAL position.

4.Start the firmware upgrade procedure again (see page 66).

67

Page 83
Image 83
ATEN Technology KM0832 user manual Upgrade Failed, Firmware Upgrade Recovery