74

Control System Menu

 

IR to Flasher Out

 

COMMON CONTROL

 

 

 

1

Control 1

Any

Zone

On

2

Control

2

Any

Zone

On

3

Flasher

Out

Selected Input

4 IR to flasher Out

Off

front panel remote

 

internal control only

 

↑↓ next item

adjust

←→

MENU setup control

 

1.Use the Up/Down keys to highlight IR to Flasher Out.

2.Use the Left/Right keys to pick from the available options of on or off.

If front Panel IR to flasher outputs is set to ON, any IR received by the front panel will pass through the

CT Receiver to the flasher outputs according the the selected input. When set to OFF Non-B&K IR com- mands will not be passed through to flasher outputs.

Regardless of this setting B&K will always respond to its own IR commands. The default is set to no because of possible optical interference.

Optical feedback occurs when IR interference from the sun, light fixture or plasma TV is present. Interference can also occur if a sensor and an emitter/flasher are very close together. If IR commands need to be relayed from the front panel to the back panel IR flasherss, select YES and test operation.

There are two possible situations you may run into:

1.Optical Feedback - Symptom: intermittent operation. To cure the feedback you must put blocking covers on all of the flasher/emitters near the front panel of the CT Receiver. Do not attempt to block IR with black electrical tape; it is generally transparent to IR. A hard plastic or tin foil is a good method for blocking IR. If you are experiencing intermittent operation, check all IR sensors for stray optical input.

2.Wrong Carrier - Symptom is no or intermittent operation. To verify this, first contact the manufac- turer and check on the carrier frequency of the original remote control. If it is not between 32kHz and 42kHz, you a may not be able to use the B&K front panel sensor. For example, the front panel sensor is probably not compatible with RCA or Proscan products with 56k carrier frequencies. Substitute an external Niles or Xantech, Elan wide-band IR sensor instead.

B & K