DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

NOTE: The auto connect port has priority over the login setup menu. If Auto Connect Port is enabled, the header and main menu are automatically disabled.

IMPORTANT: Auto Connect Port works with the DS71 upon dial- up or EIA-232 connection. If a DS71-MD2 is installed in the DS- Series Unit, the auto connect feature works only upon dial-up connection. Auto connect port will not work with a DS71-MD2

serial connection.

Select # 4, “Auto Connect Port," from the selection menu, followed by <cr>. The following Auto Connect Port menu appears:

Auto Connect Port is

Module 2, Port 1

Auto Connect is

Enabled

Change Auto Connect Port

1

Enabled/Disabled.....…..................2

Exit...............................…..............X,CR

Enter Request :

 

The DS71 series module displays the current auto connect port and its current status. To change the auto connect port module number and port number, select #1, “Change Auto Connect Port,” followed by <cr>. The DS71 or DS71-MD2 module responds:

Auto Connect Port is ............. Module 2, Port 1

Enter Auto Connect Module (2 to 9):

Enter the module to connect automatically, followed by <cr>. The DS71 or DS71-MD2 module responds:

Enter Auto Connect Port (1 to 4):

Enter the port to connect automatically, followed by <cr>. The DS71 or DS71-MD2 module stores the new settings in non- volatile memory and returns to the Auto Connect Port menu.

43