DS-RPC OWNER’S MANUAL

DETAILED OPERATION AND CONFIGURATION

__________________________________________________________________________________________

Set Word Size by selecting #3, “Set Word Size.” The DS71-MD2 displays the following list of available word sizes:

1 For 5

2 For 6

3 For 7

4 For 8

Enter the corresponding number for the desired word size. The DS71 responds with the new configuration status:

Module 1 Serial Port Configuration :

Port

Device

Baud

Word

Stop

Parity

Xon/

Xoff/

Line

Drive

 

Name

Rate

Size

Bits

 

Xmit

Recv

DTR

RTS

 

 

 

 

 

 

 

 

 

 

2

Host MODEM

115.2K

8

1

None

Off

Off

High

High

Exit/Save..….......1

Set Parity...….........5

 

 

 

 

 

Set Baud Rate….2

Set Xon/Xoff….......6

 

 

 

 

 

Set Word Size….3

RTS Line Driver....7

 

 

 

 

 

Set Stop Bits..…..4

DTR Line Driver...8

 

 

 

 

 

Enter Request :

 

 

 

 

 

 

 

 

To permanently save configuration changes, select #1, “Exit/Save,” from the selection menu, followed by <cr>. The DS71-MD2 responds:

Change Host Device to Match NEW Configuration

Before Answering this Request

Save Changes Permanently ? (Y/N) :

IMPORTANT: This message reminds you to change the serial port configuration of the host terminal to match the new configuration changes made to the serial port on the host module. If they do not match, the DS71-MD2 will be unable to interpret the next command, and you will be unable to access any connected unit. If this happens, recycle power and reconfigure the unit. Make any necessary changes to the host device before answering "Save Changes Permanently?"

33

Page 41
Image 41