Trouble-Shooting Flowchart

The flowchart below may help you quickly isolate problems and direct you to solutions. If you work through the flowchart and still experience difficulty, refer to the Troubleshooting chart in the next section.

If the M MI is not updating,

m ake sure the correct version of the D DE Server is running.

No

Check WW Logger for

 

messages w ith the

 

current device name.

Device is either not

 

configured or is

 

deactivated.

 

Stop the D DE Server. C heck

 

View: Configuration: DeviceInfo:

 

DevieNam e. Add the device

 

name if not present or activate

 

by enabling the check box.

 

The DDE Server

Yes accepted the link and is trying to collect data.

Check W WLogger or the display for timeouts on that device .

Yes

No

Server is busy collecting data for other devices. W ait a few seconds.

Is the device present? (Make sure spelling is correct.)

No

Stop D DE Server and add device.

Yes

Check if the device is activated. Note the port num ber.

Check W W Logger for any messages for that port.

Yes

Com m unication Problem s. Check the following:

M odbus Address Baudrate on the port Cables

Is the com m port connected? If using Port Server, check for network problem s.

Device specific settings

No

Check if the

No

mnem onic is

 

 

 

 

present in the

 

 

Server.

 

 

Yes

You have the wrong

 

configuration file.

 

 

Athird-party application is using the port. Close the application and restart the client.

Close all applications and restart them . C heck to see if the problem still exists.

58 Chapter Five - Troubleshooting

DDE Server User’s Guide