Ciprico 4105 Series user manual Install and Rebuild a Disk Drive Module

Models: 4105 Series

1 131
Download 131 pages 9.38 Kb
Page 97
Image 97
Install and Rebuild a Disk Drive Module

MediaVault 4105 User Manual

Maintenance

Install and Rebuild a Disk Drive Module

For Disk Drive Modules in RAID 0 Mode

A failed disk drive module in RAID 0 mode is indicated by a series of beeps. The beep indicate the number of the drive that failed. As the beeps occur, the LED nearest the defective disk drive module is illuminated.

1.Gently insert the new disk drive module into the bay.

2.Push down on the handle while pushing the disk drive module inwards, until a “click” is heard.

3.Reinstall the front panel of the MV 4105.

4.Apply power to the MV 4105 (the beeps should no longer be heard).

5.Apply power to the host computer.

CAUTION: The previous volume might appear on the monitor. Do not attempt to use this volume! The data on this volume is corrupt.

Format/partition/stripe the array using the procedures described in Chapter 6, Configuration. Restore data to the array if a backup is available.