Ciprico 4105 Series user manual For Disk Drive Modules in RAID 3 Mode

Models: 4105 Series

1 131
Download 131 pages 9.38 Kb
Page 98
Image 98
For Disk Drive Modules in RAID 3 Mode

Maintenance

MediaVault 4105 User Manual

For Disk Drive Modules in RAID 3 Mode

This procedure assumes that the MV MV 4105 is formatted in a RAID 3 mode, and is running at least 2.7 firmware version.

A failed disk in RAID 3 mode is indicated by three sets of beeps (each set of beeps will be the number of the disk drive module) when the MV 4105 is powered-up. The sets of beeps are followed by a continuous tone.

In addition, the LED located next to the failed disk drive module will flash, and the service LED for that channel will be illuminated.

1.Power-up the MV 4105 only. (The series of 3 sets of beeps are heard).

2.When a continuous tone is heard, quickly press the MODE SET button at the back of the MV 4105 once. The continuous tone is silenced.

3.Remove the replacement disk drive module from its protective anti- static bag. (Save the bag, for returning the defective disk drive module).

4.Gently insert the replacement disk drive module in the bay.

5.Push down the handle while gently inserting the disk drive module, until a “click” is heard.

6.Install the front panel onto the MV 4105.

7.Press and hold the MODE SET button until two beeps are heard. Release the button.

8.All of the drive LEDs for that channel will illuminate. This indicates that the rebuild (reconstruction) process has begun.

8-6

MV 4105_Ciprico Inc.

Page 98
Image 98
Ciprico 4105 Series user manual For Disk Drive Modules in RAID 3 Mode