Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 3 Message and Recovery Proced ures
PLATFORM_PBR Messages
PLATFORM_PBR Messages
This section contains policy based routing (PBR) messages.
Error Message PLATFORM_PBR-2-NO_RMAP: Cannot create PBR data structures for
route-map [chars].
Note This message applies only to Catalyst 3750 and 3560 switches.
Explanation The PBR manager could not allocate the internal data structures for this route-map. A
likely cause is lack of available memory. [chars] is the route-map.
Recommended Action Simplify the configuration so that it requires less memory.
Error Message PLATFORM_PBR-3-INSTALL_FAIL: Policy route-map [chars] not installed in
hardware.
Note This message applies only to Catalyst 3750 and 3560 switches.
Explanation The PBR manager was unable to install the complete route-map in hardware, so the
packets are forwarded to the CPU for processing. [chars] is the route-map.
Recommended Action Simplify route-map configurations. For example, use the same route-map on
multiple interfaces.
Error Message PLATFORM_PBR-3-NO_LABEL: Cannot allocate label for route-map [chars].
Note This message applies only to Catalyst 3750 and 3560 switches.
Explanation The PBR manager could not allocate a label for this route- map. As a result, the hardware
cannot be programmed to implement policy routing. There is a li mit of 247 labels for policy routing.
[chars] is the route-map.
Recommended Action Simplify the configuration with label sharing. Use the same route-maps on
multiple interfaces, if possible.