3-5
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 3 Message and Recovery Procedures
ACLMGR Messages
Error Message ACLMGR-3-IECPORTLABELERROR: ACL labels are out-of-sync on interface
[chars], label [dec] is not available on asic [dec].
Explanation An internal software error has occurred. [chars] is the interface name. The first [dec] is
the label associated with the ACL, and the second [dec] is the ASIC number.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with th e gathered
information. For more information about these online tools and about contacting Cisco, see the “Error
Message Traceback Reports” section on page 2-7.
Error Message ACLMGR-3-INSERTFAIL: Insert of access-map [chars] #[dec] into [chars]
label [dec] failed.
Explanation The system ran out of CPU memory when trying to merge sections of an access map.
The first [chars] is the map name, and the second [chars] is the direction in which the map was
applied. The first [dec] is the entry number, and the second [dec] is the label number.
Recommended Action Reduce other system activity to ease m emory demands. For example, remove
any ACLs that have been defined but are not now used. Use simpler ACLs with fewer access control
entries (ACEs). Use fewer VLANs, and remove any unneeded VLANs from the VLAN database.
Error Message ACLMGR-3-INTTABLE: Not in truth table: VLMAP [dec] RACL [dec] Mcb [dec]
Feat [dec].
Explanation An unrecoverable software error occurred while trying to merge the configured input
features. [dec] are internal action codes.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Enter the show
running-config user EXEC command to gather data that might help identify the nature of the error.
Use the Bug Toolkit to look for similar reported problems. If you still require assistance, open a case
with the TAC, or contact your Cisco technical support representative, and provide the representative
with the gathered information. For more information about these online tools and about contacting
Cisco, see the “Error Message Traceback Reports” section on page 2-7.
Error Message ACLMGR-3-INVALIDPARAM: Invalid [chars] [int] encountered
Explanation The access control list (ACL) manager has encountered an invalid parameter value.
[chars] is the parameter name, and [int] is the para meter value.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with th e gathered
information. For more information about these online tools and about contacting Cisco, see the
“Error Message Traceback Reports” section on page 2-7.