3-60
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 3 Message and Recovery Proced ures
IDBMAN Messages
Explanation There is an internal error that caused an interface that is not an aggregate port to be used
for aggregate port operations. [chars] is the interface name, and ([dec] / [dec]) are the slot and port
number (slot/port).
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with th e gathered
information. For more information about these online tools and about contacting Cisco, see the “Error
Message Traceback Reports” section on page 2-7.
Error Message IDBMAN-3-PORTNOTINAGGPORT: [chars]([dec] / [dec]) is not present in
Aggport [chars [([dec] / [dec]).
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 296 0 switches.
Explanation An internal error has been detected. A port that was supposed to be in an aggregate port
was found not to be. The first [chars] is the interface name, and the second [chars] is the port-channel
name. The ([dec] / [dec]) are the slot and port numbers (slot/port).
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with th e gathered
information. For more information about these online tools and about contacting Cisco, see the “Error
Message Traceback Reports” section on page 2-7.
Error Message IDBMAN-3-VLANNOTSET: [chars]: Vlan [dec] not set since it already has
Vlan [dec].
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 296 0 switches.
Explanation An interface VLAN was not set to the requested value because of an internal error.
[chars] is the interface name. The first [dec] is the recently configured VLAN ID, and the second
[dec] is the currently assigned VLAN ID.
Recommended Action Copy the message exactly as it appears on the console or in the system log.
Research and attempt to resolve the error by using the Output Interpreter. Use the Bug Toolkit to
look for similar reported problems. If you still require assistance, open a case with the TAC, or
contact your Cisco technical support representative, and provide the representative with th e gathered
information. For more information about these online tools and about contacting Cisco, see the “Error
Message Traceback Reports” section on page 2-7.