3-116
Catalyst 3750, 3560, 3550, 2975, 2970, and 2960 Switch System Message Guide
OL-8551-04
Chapter 3 Message and Recovery Proced ures
QOSMGR Messages
Error Message QOSMGR-4-HARDWARE_NOT_SUPPORTED: Hardware limitation has reached for
policymap [chars].
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 296 0 switches.
Explanation The policy-map configuration has exceeded the limitation of the hardware. You
configured more QoS ACL entries than the number specified in the Switch Database Management
(SDM) template. [chars] is the policy-map name.
Recommended Action Reconfigure the class map or the policy map, and re duce the number of QoS
ACLs.
Error Message QOSMGR-4-MATCH_NOT_SUPPORTED: Match type is not supported in classmap
[chars].
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 296 0 switches.
Explanation An unsupported match type was entered. Only the access-group acl-index-or-name, ip
dscp dscp-list, and ip precedence ip-precedence-list match types are supported with the match
class-map configuration command. [chars] is the cla ss-map name.
Recommended Action Reconfigure the class map; use only the match access-group, match ip dscp,
and match ip precedence class-map configuration commands within the class map.
Error Message QOSMGR-4-NOT_SUPPORTED: Action ’[chars]’ is not supported for a
policymap attached to output side.
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 296 0 switches.
Explanation A set or trust policy-map class configuration command was configured in a policy map
and attached to an egress interface. A warning message is logged, and the actions do not take effect.
This is a hardware limitation. [chars] is either the set or trust action.
Recommended Action Do not configure a set or trust policy-map class configuration command in a
policy map and attach it to an egress interface. These policy-map actions a re supported only on
ingress interfaces.
Error Message QOSMGR-4-POLICER_PLATFORM_NOT_SUPPORTED: Policer configuration has
exceeded hardware limitation for policymap [chars].
Note This message applies only to Catalyst 3750, 3560, 2975, 2970, and 296 0 switches.