Appendix C Troubleshooting the Installation
Getting Started
Getting Started
When the initial system boot is complete, verify the following:
•Power supplies are supplying power to the system.
•The system fan assembly is operating.
•System software boots successfully.
If all of these conditions are met and the hardware installation is complete, refer to the Catalyst 4500 Series Switch Cisco IOS Software Configuration Guide and the Catalyst 4500 Series Switch Cisco IOS Command Reference publications to troubleshoot the software. However, if any of these conditions are not met, use the procedures in this chapter to isolate and, if possible, resolve the problem.
Problem Solving to the System Component Level
The key to success when troubleshooting the system is to isolate the problem to a specific system component. The first step is to compare what the system is doing to what it should be doing. Because a startup problem can usually be attributed to a single component, it is more efficient to isolate the problem to a subsystem rather than troubleshoot each separate component in the system.
The switch consists of the following subsystems:
•Power
•Fan assembly
Identifying Startup Problems
When you connect the power cords to the switch, follow these steps:
Step 1 Set the power switches to the on position (AC powered systems only).
Step 2 Verify that power is available to the power supplied from the site AC or DC source. Turn on breakers and fuses if necessary.
Step 3 Listen for the system fan assembly. If you do not immediately hear the system fan assembly begin to operate, see “Troubleshooting the Power Supply” section on page
Step 4 If you determine that the power supplies are functioning normally and that the fan tray is faulty, contact a customer service representative. If the system fan assembly does not function properly at initial startup, there are no installation adjustments that you can make.
Catalyst 4948E and Catalyst
|
|
| |
|
|