Appendix A Power Supply Specifications
300 W 
Table 
| Item | Specification | 
| 
 | 
 | 
| Power supply LEDs | 
 | 
| INPUT OK | •  | 
| 
 | supply has detected that the source AC voltage is within limits. | 
| 
 | The input voltage is ≥ 82 VAC ±3 VAC. | 
| 
 | •  | 
| 
 | two situations occurs: | 
| 
 | – In chassis that are equipped with dual power supplies, and | 
| 
 | both are powered on, either INPUT OK LED is lit red if its | 
| 
 | source AC voltage falls below 73 VAC (±3 VAC). | 
| 
 | – In chassis that are equipped with dual power supplies and | 
| 
 | one power supply is powered on and the other power supply | 
| 
 | is powered off, the INPUT OK LED is lit red, rather than | 
| 
 | unlit, on the power supply that is turned off. | 
| 
 | •  | 
| 
 | the INPUT OK LED is off when source AC voltage falls below | 
| 
 | 73 VAC (±3 VAC), is not present with the power on/off switch | 
| 
 | turned on, or the power supply is turned off. | 
| OUTPUT OK | •  | 
| 
 | (11.30 VDC < output voltage < 12.85 VDC). | 
| 
 | •  | 
| 
 | three situations occurs: | 
| 
 | – In chassis that are equipped with a single power supply, the | 
| 
 | 12 VDC output is out of tolerance (< 11.30 VDC or | 
| 
 | > 12.85 VDC). | 
| 
 | – In chassis that are equipped with dual power supplies and | 
| 
 | one power supply is powered on and the other power supply | 
| 
 | is powered off, the OUTPUT OK LED is lit red, rather than | 
| 
 | unlit, on the power supply that is turned off. | 
| 
 | – The OUTPUT OK LED is also lit red when a power supply | 
| 
 | fan failure is detected. A fan failure is triggered when the | 
| 
 | fan rotation drops below 7047 RPM ± 150 RPM. | 
| 
 | •  | 
| 
 | the OUTPUT OK LED is off when the power supply is turned | 
| 
 | off. | 
| 
 | 
 | 
| Weight | 2 lb (0.9 kg) | 
| 
 | 
 | 
1.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch.
Catalyst 4948E and Catalyst 
| 
 | ||
| 
 | 