Appendix A Power Supply Specifications
300 W
Table
Item | Specification |
|
|
Power supply LEDs |
|
INPUT OK | • |
| supply has detected that the source AC voltage is within limits. |
| The input voltage is ≥ 82 VAC ±3 VAC. |
| • |
| two situations occurs: |
| – In chassis that are equipped with dual power supplies, and |
| both are powered on, either INPUT OK LED is lit red if its |
| source AC voltage falls below 73 VAC (±3 VAC). |
| – In chassis that are equipped with dual power supplies and |
| one power supply is powered on and the other power supply |
| is powered off, the INPUT OK LED is lit red, rather than |
| unlit, on the power supply that is turned off. |
| • |
| the INPUT OK LED is off when source AC voltage falls below |
| 73 VAC (±3 VAC), is not present with the power on/off switch |
| turned on, or the power supply is turned off. |
OUTPUT OK | • |
| (11.30 VDC < output voltage < 12.85 VDC). |
| • |
| three situations occurs: |
| – In chassis that are equipped with a single power supply, the |
| 12 VDC output is out of tolerance (< 11.30 VDC or |
| > 12.85 VDC). |
| – In chassis that are equipped with dual power supplies and |
| one power supply is powered on and the other power supply |
| is powered off, the OUTPUT OK LED is lit red, rather than |
| unlit, on the power supply that is turned off. |
| – The OUTPUT OK LED is also lit red when a power supply |
| fan failure is detected. A fan failure is triggered when the |
| fan rotation drops below 7047 RPM ± 150 RPM. |
| • |
| the OUTPUT OK LED is off when the power supply is turned |
| off. |
|
|
Weight | 2 lb (0.9 kg) |
|
|
1.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch.
Catalyst 4948E and Catalyst
| ||
|