Appendix A Power Supply Specifications

300 W AC-Input Power Supply (PWR-C49E-300AC-R)

Table A-1

300 W AC-Input Power Supply Specifications (continued)

 

 

 

Item

 

Specification

 

 

Power supply LEDs

 

INPUT OK

 

Green—The INPUT OK LED is lit green when the power

 

 

supply has detected that the source AC voltage is within limits.

 

 

The input voltage is 82 VAC ±3 VAC.

 

 

Red—The INPUT OK LED is red when either of the following

 

 

two situations occurs:

 

 

In chassis that are equipped with dual power supplies, and

 

 

both are powered on, either INPUT OK LED is lit red if its

 

 

source AC voltage falls below 73 VAC (±3 VAC).

 

 

In chassis that are equipped with dual power supplies and

 

 

one power supply is powered on and the other power supply

 

 

is powered off, the INPUT OK LED is lit red, rather than

 

 

unlit, on the power supply that is turned off.

 

 

Off—In chassis that are equipped with a single power supply,

 

 

the INPUT OK LED is off when source AC voltage falls below

 

 

73 VAC (±3 VAC), is not present with the power on/off switch

 

 

turned on, or the power supply is turned off.

OUTPUT OK

Green—The 12 VDC output is within margins

 

 

(11.30 VDC < output voltage < 12.85 VDC).

 

 

Red—The OUTPUT OK LED is red when any of the following

 

 

three situations occurs:

 

 

In chassis that are equipped with a single power supply, the

 

 

12 VDC output is out of tolerance (< 11.30 VDC or

 

 

> 12.85 VDC).

 

 

In chassis that are equipped with dual power supplies and

 

 

one power supply is powered on and the other power supply

 

 

is powered off, the OUTPUT OK LED is lit red, rather than

 

 

unlit, on the power supply that is turned off.

 

 

The OUTPUT OK LED is also lit red when a power supply

 

 

fan failure is detected. A fan failure is triggered when the

 

 

fan rotation drops below 4150 RPM ± 150 RPM.

 

 

Off—In chassis that are equipped with a single power supply,

 

 

the OUTPUT OK LED is off when the power supply is turned

 

 

off.

 

 

 

Weight

 

2 lb (0.9 kg)

 

 

 

1.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch.

Catalyst 4948E and Catalyst 4948E-F Switch Installation Guide

 

A-4

OL-21561-02

 

 

 

Page 80
Image 80
Cisco Systems 4948E-F manual Input OK, Output OK