Appendix A Power Supply Specifications
300 W
Table | 300 W | |
|
|
|
Item |
| Specification |
|
| |
Power supply LEDs |
| |
INPUT OK |
| • |
|
| supply has detected that the source AC voltage is within limits. |
|
| The input voltage is ≥ 82 VAC ±3 VAC. |
|
| • |
|
| two situations occurs: |
|
| – In chassis that are equipped with dual power supplies, and |
|
| both are powered on, either INPUT OK LED is lit red if its |
|
| source AC voltage falls below 73 VAC (±3 VAC). |
|
| – In chassis that are equipped with dual power supplies and |
|
| one power supply is powered on and the other power supply |
|
| is powered off, the INPUT OK LED is lit red, rather than |
|
| unlit, on the power supply that is turned off. |
|
| • |
|
| the INPUT OK LED is off when source AC voltage falls below |
|
| 73 VAC (±3 VAC), is not present with the power on/off switch |
|
| turned on, or the power supply is turned off. |
OUTPUT OK | • | |
|
| (11.30 VDC < output voltage < 12.85 VDC). |
|
| • |
|
| three situations occurs: |
|
| – In chassis that are equipped with a single power supply, the |
|
| 12 VDC output is out of tolerance (< 11.30 VDC or |
|
| > 12.85 VDC). |
|
| – In chassis that are equipped with dual power supplies and |
|
| one power supply is powered on and the other power supply |
|
| is powered off, the OUTPUT OK LED is lit red, rather than |
|
| unlit, on the power supply that is turned off. |
|
| – The OUTPUT OK LED is also lit red when a power supply |
|
| fan failure is detected. A fan failure is triggered when the |
|
| fan rotation drops below 4150 RPM ± 150 RPM. |
|
| • |
|
| the OUTPUT OK LED is off when the power supply is turned |
|
| off. |
|
|
|
Weight |
| 2 lb (0.9 kg) |
|
|
|
1.The kVA rating listed for the power supply should be used as the sizing criteria for both UPS outputs as well as standard circuits and transformers to power a switch.
Catalyst 4948E and Catalyst
|
|
| |
|
|