Supervisor Engine 2 LEDs (continued)

Chapter 2 Route Switch Processors and Supervisor Engines

Supervisor Engine 2

Table 2-5

Supervisor Engine 2 LEDs (continued)

 

 

 

 

LED

 

Color

Description

 

 

 

 

SYSTEM1

 

Green

All chassis environmental monitors are reporting OK.

 

 

 

 

 

 

Orange

The power supply or power supply fan failed.

 

 

 

Incompatible power supplies are installed.

 

 

 

The redundant clock failed.

 

 

 

One VTT2 module has failed or the VTT module temperature minor

 

 

 

threshold has been exceeded.3

 

 

Red

Two VTT modules failed or the VTT module temperature major

 

 

 

threshold has been exceeded.3

 

 

 

The temperature of the supervisor engine major threshold has been

 

 

 

exceeded.

 

 

 

 

CONSOLE

 

Green

The supervisor engine is operational and active.

 

 

 

 

 

 

Orange

The supervisor engine is in standby mode.

 

 

 

 

PWR MGMT1

 

Green

Sufficient power is available for all modules.

 

 

 

 

 

 

Orange

Sufficient power is not available for all modules.

 

 

 

 

SWITCH LOAD

 

-

If the system is operational, the switch load meter indicates (as an

 

 

 

approximate percentage) the current traffic load over the backplane.

 

 

 

 

PCMCIA

 

-

The PCMCIA LED is lit when no PCMCIA card is in the slot and goes

 

 

 

off when you insert a card.

 

 

 

 

LINK

 

Green

The port is operational.

 

 

 

 

 

 

Orange

The link has been disabled by software.

 

 

 

 

 

 

Flashing

The link is bad and has been disabled due to a hardware failure.

 

 

orange

 

 

 

 

 

 

 

Off

No signal is detected.

 

 

 

 

1.The SYSTEM and PWR MGMT LED indications on a redundant supervisor engine are synchronized to the active engine.

2.VTT = voltage termination. The VTT module terminates signals on the system switching bus.

3.If no redundant supervisor engine is installed and there is a VTT module minor or major overtemperature condition, the system shuts down.

 