2.5.2 Switch Setting

2.5.2.1 Advanced

Miscellaneous Setting:
MAC Address Age-out Time: Type the number of seconds that an inactive MAC address remains in the
switch's address table. The valid range is 300~765 seconds. Default is 300 seconds.
Max bridge transit delay bound control: Limit the packets queuing time in switch. If enable, the
packets queued exceed will be drop. These valid values are 1sec, 2 sec, and 4 sec and off. Default is 1
seconds.
NOTE: Make sure of “Max bridge transit delay bound control” is enabled before enable Delay Bound,
because Enable Delay Bound must be work under “Max bridge transit delay bound control is enabled”
situation.
Broadcast Storm Filter: To configure broadcast storm control, enable it and set the upper threshold for
individual ports. The threshold is the percentage of the port's total bandwidth used by broadcast traffic.
When broadcast traffic for a port rises above the threshold you set, broadcast storm control becomes
active. The valid threshold value is 5%, 10%, 15%, 20%, 25% and off.
Priority Queue Service settings:
First Come, First Serve: The sequence of packets sent is depending on arrive orders.