If the environmental status is not normal, the system reports the worst-case status level. Following is a sample overvoltage warning:

Router# show environment

Warning: +3.3 V measured at +3.41 V

The show environment last command retrieves and displays the NVRAM log, which provides a record of environmental status readings. Air temperature is measured and displayed, and the voltage supplied by the power supply is also displayed.

Following is sample output of the show environment last command:

Router# show environment last

chassis

core

previously measured at 34C/93F

chassis

inlet

previously measured at 28C/82F

chassis

outlet 1

previously measured at 31C/87F

chassis outlet 2

previously measured at 33C/91F

+2.5 V

 

previously measured at +2.59

+3.3 V

 

previously measured at +3.32

+5.15

V

 

previously measured at +5.13

+12.3

V

 

previously measured at +12.99

+12.3

V

 

previously measured at +12.33

-12.5

V

 

previously measured at -12.43

The show environment table command displays the temperature and voltage thresholds for each temperature sensor and for each monitored status level, which are related to those thresholds listed in Table 6-1and Table 6-2.

Following is sample output of the show environment table command:

Router#

show environment table

 

 

 

Sample Point

LowCritical

LowWarning

HighWarning

HighCritical

chassis

core

 

 

49C/120F

54C/129F

chassis

inlet

 

 

43C/109F

48C/118F

chassis

outlet 1

 

 

46C/114F

51C/123F

chassis

outlet 2

 

 

47C/116F

52C/125F

+2.5 V

 

+2.35

+2.39

+2.69

+2.72

+3.3 V

 

+3.11

+3.19

+3.39

+3.47

+5.15

V

 

+4.88

+5.00

+5.23

+5.39

+12.3

V

 

+11.53

+11.77

+12.76

+13.05

+12.3

V

 

+11.53

+11.77

+12.76

+13.05

-12.5

V

 

-10.20

-11.24

-13.71

-14.33

Note Temperature ranges and values are subject to change.

The show environment all command displays an extended report that includes temperature readings and voltage readings.

Following is sample output of the show environment all command:

Router# show environment all

Power Supply:

Power supply is standard power supply. Unit is on.

Temperature readings:

 

 

chassis

core

measured at

33C/91F

chassis

inlet

measured at

27C/80F

 

 

 

chassis outlet 1

measured at

30C/86F

 

 

 

chassis outlet 2

measured at

32C/89F

 

 

 

Cisco uBR7100 Series and Cisco uBR7100E Series Universal Broadband Router Hardware Installation Guide

 

 

 

 

 

 

 

 

 

 

 

6-4

 

 

 

OL-5916-01

 

 

 

 

 

 

Page 80
Image 80
Cisco Systems UBR7100E manual Router# show environment last