Step 9 Connect the power supply cords.

Chapter 3 Installing the Switch in a Rack

System Ground Connection Guidelines

Ensure that the grounding lug and the attached wire will not interfere with other switch hardware or rack equipment.

Step 7 Tighten the screws to secure the grounding lug to the grounding pad.

Step 8 Repeat steps 1 through 3 to prepare the other end of the grounding wire and connect it to an appropriate grounding point at your site to ensure adequate earth ground for the switch.

Step 9 Connect the power supply cords.

The switch comes on when the cords are connected and the power supply on/off switch is on.

Note This equipment is suitable for connection to intra-building wiring only.

Note If you are using a DC power supply, the DC return connection to this system should remain isolated from the system frame and chassis (DC-I).

This completes the installation of the Catalyst 4500 series switches.

At this point you should use the RJ-45-to-RJ-45 rollover cable to connect the console port to a PC that runs terminal emulation software. Configure your terminal emulation program for 9600 baud, 8 data bits, no parity, and 1 stop bit. With this console connection, you can configure the switch as discussed in the software configuration guide appropriate for your switch’s software release, and monitor the software as the switch goes through its startup routine. The pinout for the console port is detailed in the module installation guide at: http://www.cisco.com/univercd/cc/td/doc/product/lan/cat4000/hw_doc/mod_inst /0aspecs.htm#wp1003732

 

 

Catalyst 4500 Series Switches Installation Guide

 

 

 

 

 

 

78-14409-08

 

 

3-25

 

 

 