Chapter 1 Product Overview
Power Supplies
For a 1400 W DC power supply, the main power switch has an input range of
The supervisor engine monitors the status of each power supply and provides a status report through the switch software. For more details on how the supervisor engine monitors the power supplies, refer to the “Environmental Monitoring and Power Management” chapter of the Catalyst 4500 Series Switch Cisco IOS Software Configuration Guide.
1400 W DC Triple-input Power Supply Operational Modes
The C4500 1400 W DC Triple Input SP Power Supply (data only) allows added redundancy by providing terminals for two DC inputs rated at 15 A and one rated at 12.5 A per power supply.
This power supply has five operational modes depending on the inputs receiving power. When all three inputs are active, at input voltages greater than
|
|
| Table | Input Modes |
|
|
| |
|
|
|
|
|
|
|
| |
|
|
| Input | Input |
| Maximum Total Output | ||
|
|
| Mode | Number | Input Configuration | Power | ||
|
|
|
|
|
| |||
1 | 1 | 1 x 12.5 A | 386 W @ | |||||
|
|
|
|
|
| 412 W @ | ||
|
|
|
|
|
| |||
2 | 2 OR 3 | 1 x 15 A | 466 W @ | |||||
|
|
|
|
|
| 495 W @ | ||
|
|
|
|
|
| |||
3 | 1, 2 OR 3 | 1 x 12.5 A and | 845 W @ | |||||
|
|
|
|
| 1 x 15 A | 908 W @ | ||
|
|
|
|
|
| |||
4 | 2, 3 | 2 x 15A | 914 W @ | |||||
|
|
|
|
|
| 990 W @ | ||
|
|
|
|
|
| |||
5 | 1, 2, 3 | 1 x 12.5A and | 1294 W @ | |||||
|
|
|
|
| 2 x 15 A | 1400 W @ | ||
|
|
|
|
|
|
|
|
|
|
| Catalyst 4500 Series Switches Installation Guide |
|
|
| |||
|
|
|
|
| ||||
|
|
|
|
|
| |||
|
|
|
|
|
|