iDP3420/3421/3423 User ’s Manual
ESC " ⁄ " n "data" CR or LF
[Function] | Defining the message |
|
[Code] | <1B>H <2F>H n "data" CR or LF |
|
[Range] | 1 ≤ n ≤ 10 |
|
[Outline] | This command can define up to a | If the value of n is specified |
| beyond the range, the data following n will be treated as the print data. | |
| Once the message is defined, it remains valid until it is redefined. | The data should end with |
| CR (0DH) or LF (0AH). If the data exceeds 50 bytes, the subsequent data will be treated as | |
| the print data. |
|
| Once the message is defined, it remains valid until it is redefined or the download deletion | |
| command (ESC DC2 n1 n2) is executed. |
|
ESC DC3 n
[Function] | Printing the message |
[Code] | <1B>H <13>H n |
[Range] | 1 ≤ n ≤ 10 |
[Function] | This command prints a message. If the value of n is specified beyond the range, the |
| message will not be printed. |
86 | CITIZEN |