iDP3420/3421/3423 User ’s Manual

ESC " ⁄ " n "data" CR or LF

[Function]

Defining the message

 

[Code]

<1B>H <2F>H n "data" CR or LF

 

[Range]

1 ≤ n ≤ 10

 

[Outline]

This command can define up to a 50-byte message in one line.

If the value of n is specified

 

beyond the range, the data following n will be treated as the print data.

 

Once the message is defined, it remains valid until it is redefined.

The data should end with

 

CR (0DH) or LF (0AH). If the data exceeds 50 bytes, the subsequent data will be treated as

 

the print data.

 

 

Once the message is defined, it remains valid until it is redefined or the download deletion

 

command (ESC DC2 n1 n2) is executed.

 

ESC DC3 n

[Function]

Printing the message

[Code]

<1B>H <13>H n

[Range]

1 ≤ n ≤ 10

[Function]

This command prints a message. If the value of n is specified beyond the range, the

 

message will not be printed.