ESC "c" "4" n

[Function]

Selecting the paper near end sensor valid for print stop

 

 

 

[Code]

<1B>H<63>H<34>H n

 

 

 

 

[Range]

0 ≤ n ≤ 255

 

 

 

 

 

[Outline]

This command selects the no-paper detector state in which printing should be stopped.

 

 

 

 

 

 

 

 

 

 

Bit

Function

 

Value

 

 

 

0

 

1

 

 

 

 

 

 

 

 

 

0

Paper near end

Disabled

 

Enabled

 

 

 

1

Undefined

 

 

 

 

2

Undefined

 

 

 

 

3

Undefined

 

 

 

 

4

Undefined

 

 

 

 

5

Undefined

 

 

 

 

6

Undefined

 

 

 

 

7

Undefined

 

 

[Default]

n = 1

 

 

 

 

 

ESC "c" "5" n

[Function]

Selecting the panel switch enable/disable

[Code]

<1B>H <63>H <35>H n

[Range]

0 ≤ n ≤ 255

[Outline]

This command enables/disables the panel switches. n is valid only for the least significant

 

bit.

 

Setting n = 1 disables the panel switches.

 

Setting n = 0 enables the panel switches.

[Caution]

If the panel switches are disabled with this command, the LF switch will be disabled.

 

Therefore, the paper cannot be fed by the LF switch.

[Default]

n = 0