Installing a Precooler ( O p t i o n a l )

(continued)

7Connect the water discharge or return line with the pressure relief valve to the precooler outlet. Use the bracket supplied to secure the pressure relief valve and discharge line to the back of the dryer.

Precooler installed on a D 15, 25,

Precooler installed on a D 75 and

100 dryer without a flow control

and 50 dryer without a flow control

 

8Install the plastic precooler cap over the water connections.

Pressure Relief Valve Precooler installed on a D 15, 25, (Release Pressure 100 psi

[689.5 k Pa])

Precooler with a flow control valve

Precooler with a flow control valve

installed on a D 15, 25, and 50 dryer

installed on a D 75 and 100 dryer

IMPORTANT: For drying setpoint temperatures above 150°F (65.6°C), the precooler must be bypassed by connecting the dryer supply hose from the dryer directly to the hopper inlet.