Control Function Descriptions ( c o n t i n u e d )

S c r e e n

Screen 28-43 require access code 755.

SCREEN 29 (Test Mode Screen)

H Manual backgroundManual background off Manual backgroundManual background 2

SCREEN 30 (Test Mode Screen)

H Manual backgroundManual background off Manual backgroundManual background 3

SCREEN 31 (Test Mode Screen)

H Manual backgroundManual background off Manual backgroundManual background 4

SCREEN 32 (Test Mode Screen)

H Manual backgroundManual background off Manual backgroundManual background 5

SCREEN 33 (Test Mode Screen)

H Manual backgroundManual background off Manual backgroundManual background 6

F u n c t i o n

This is the Test Mode screen for the process heater. By pressing the + or - keys, the setting can be changed. When set to "On", the process heater output will be turned on for 3 sec. and then shut off automatically.

Note: The isolation contactor will not be pulled in so no electricity will go the heater.

The solid state relay contacts should close.

This is the Test Mode screen for the regen- eration blower. By pressing the + or - keys, the setting can be changed. When set to "On", the regeneration blower output will be turned on for 3 sec. and then shut off automatically.

This is the Test Mode screen for the regen- eration heater. By pressing the + or - keys, the setting can be changed. When set to "On", the regeneration heater output will be turned on for 3 sec. and then shut off automatically.

Note: The isolation contactor will not be pulled in so no electricity will go the heater.

The solid state relay contacts should close.

This is the Test Mode screen for the bed drive motor. By pressing the + or - keys, the setting can be changed. When set to "On", the bed drive motor output will be turned on until the limit switch makes the next valley, and then shut off automatically.

This Test Mode screen is not used in the current program.