Conair 15, 25, 50 Connecting the Air Hoses, Connecting the Water Hoses, Secure hoses with clamps

Models: 15 100 25

1 128
Download 128 pages 56.24 Kb
Page 37
Image 37
Connecting the Air Hoses

Connecting the Air Hoses

Using the two flexible hoses provided, connect the inlets and outlets of the dry- ing hopper to the dryer. If you have positioned the dryer on the floor or mount- ed it to an optional floor stand, make sure the dryer is located no more than 5 feet (1.5 m) from the hopper to reduce heat loss.

If you ordered an insulated hose, it should be installed between the dryer outlet and the hopper inlet.

If you have ordered an optional aftercooler or precooler, see Appendices C

and E.

1Attach the hose to the return air outlet at the top of the hopper labeled “From Hopper”.

2Attach the hose to the hopper’s delivery air inlet labeled “To Hopper”.

Return

Air Inlet

Return

Air Inlet

Delivery air outlet (15, 25, and 50 models)

3

Secure hoses with clamps.

The hose clamp should be secured at least 1/4 in. (0.64 cm) from the end of the inlet or outlet tube.

Delivery air outlet (75 and 100 models)

3 D e s c r i p t i o n

Connecting the Water Hoses

NOTE: Do not allow the

flexible hoses to kink or

 

 

crimp.

The optional aftercooler, flow control, and precooler require a source of cooling water and a discharge or return line. See Appendix C for information on installing and connecting water hoses to the optional aftercooler. See Appendix D for infor- mation on installing and connecting water hoses to the optional flow control. See Appendix E for information on installing and connecting water hoses to the option- al precooler.

I n s t a l l a t i o n l 3 - 1 5