6  150  120

Control Function Descriptions ( c o n t i n u e d )

S c r e e n

SCREEN 10 (Setback

Temperature Option)

6 7  145  250Manual background 150 Manual backgroundManual background 120

SCREEN 11 (Setback Options)

7 Manual backgroundManual background 145 Manual backgroundManual background 250

SCREEN 12 (Setback Load Rate Option)

8

 

5

 

7

 

 

 

 

 

F u n c t i o n

If the dryer has the setback on temperature option installed, this is the temperature setpoint for the air at the outlet of the dry- ing hopper. When this setpoint is reached, the dryer will automatically change the process setpoint to the setpoint shown on Menu number 7, Screen 11. When the temperature at the outlet of the hopper drops below the setpoint (menu number 6) by the value shown under C07, screen 22, the dryer will return to the normal drying setpoint.

If the dryer has the setback on temperature option installed, this is the temperature set- point to which the process air will revert once the air at the outlet of the hopper has reached its setpoint. (Menu number 6)

If the dryer has the optional setback on load rate option, this screen shows the number of load dumps per hour, setpoint and actual. When the actual drops below the setpoint the dryer will go into setback mode. When the actual goes above the set- point, the dryer will return to the normal process temperature.

Central

When supplied for central drying applica- tions, these functions are not available.

4 O p e r a t i o n

O p e r a t i o n l 4 - 7