Installing the Dew Point Sensor

Note: See instructions sent along with your upgrade kit

to enable this option.

Installing the Dew Point Sensor

( O p t i o n a l )

The dew point sensor can be mounted to the inside bottom right corner of the dryer back panel.

1Peal the tape from the dew point sensor block and place it in the bottom right side of the back panel as shown.

2 Route the hose near the top

of the block to the fitting near the top of the process heater tube (D 15, D 25, and D 50) or the fitting near the bottom of the process heater tube

(D 75 and D 100).

3Route the hose near the bottom of the sensor block to the 1/8" (3.18 mm) NPY hose fitting on the inlet of the process blower. The inlet is the tube toward the center of the dryer.

4The dew point sensor comes with a plug wire attached. Reference the wiring diagram to attach this wire to the proper points on the board.

Represents 15, 25, and 50 models