LUBRICATION/FILTERS/FRUIDS

Hydrostatic System Filter (Hydrostatic Drive)

Filter Change Interval

Every 200 hours (See NOTE)

NOTE: Change the filter after the first 50 hours of operation and every 200 hours of operation thereafter. Replace the filter more frequently when operating under unusual dirt and dust conditions. Your Dealer has approved genuine filters. Do not use other type filters.

HYDROSTATIC

SYSTEM

FILTER

REMOVE INSTALL

When the transmission fluid filter needs changing, change the filter as follows:

1.Drain the transmission oil. See Transmission Oil Change in this manual.

2.Remove the hydrostatic system filter by turning it counterclockwise. Use a filter wrench, if necessary.

3.Apply clean oil to the O-ring on the new filter.

4.Install the new filter. Turn the filter clockwise until the O-ring comes in contact with the filter head surface. Tighten the filter an additional 2/3 turns by hand.

5.Add the transmission oil through the fill port and check the oil level.

6.Run the engine and check for leaks.

7.After stopping the engine, check the oil level. If it is low, add clean oil.