LUBRICATION/FILTERS/FRUIDS
AIR INDUCTION SYSTEM
The air induction system components require service at different intervals according to local operating conditions.
Service Specifications
Dump Valve | Clean daily or every 10 hours |
Filter Element |
|
Clean Element | When necessary |
Replace Element | After 10 cleanings or yearly |
System Inspection | Every 200 hours or yearly whichever occurs first |
Your tractor is equipped with a
AIR CLEANER
INLET HOSE
IMPORTANT: Service the air induction system at the given service intervals. Correct maintenance will add to the life of the engine. Keep all connections on the outlet hose tight.
Dump Valve |
|
The dust in a filter case should be |
|
dumped daily using the dump valve |
|
when operating in extremely dusty | DUMP VALVE |
| |
conditions. |
|
95